Neuro-IOM-32/B

System for Intraoperative Neurophysiological Monitoring with Advanced Functionality
Neuro-IOM is a multifunctional modular platform solution for intraoperative neurophysiological monitoring (IONM). Its application allows the surgical team to be informed about possible damage of nerve tissues resulting from surgeon actions and, thus, to prevent neurological deficit. In most countries intraoperative neurophysiological monitoring is a must for various types of surgery, i.e., spine surgery, brain surgery, brainstem surgery, etc. As for the spine surgery (for example, scoliosis) the tactics is directly determined during IONM. Currently, the technique is being implemented actively in our country. Neuro-IOM is the first Russian intraoperative neurophysiological monitoring system. The large experience in development and manufacture of neurophysiological equipment helped Neurosoft company to enter the IONM market rapidly several years ago. The system was registered in Russia and then the company had got the CE mark to sell the system in European countries. Now, more than hundred of Neurosoft Neuro-IOM systems are used successfully in hospitals and other healthcare facilities of Russia, Brazil, France, Jordan, Turkey, Bulgaria and other countries.

Comprehensive solution for effective intraoperative neurophysiological monitoring

The standard configuration of Neuro-IOM (version 2) is the best solution for any type of neurological surgery. 32-channel amplifier and 4-channel transcranial electrical stimulator (up to 1000 V) with a wide range of pulse waveforms ensure the control of conduction pathways using motor evoked potentials even in the most complicated cases.

Main features:

  • 64 amplifier inputs (32 bipolar channels);
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 12 channels for electrical stimulation;
  • 2 channels for direct nerve stimulation;
  • 4 channels for transcranial electrical stimulation;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.
The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes, a PC and the software are also included to the delivery set.

Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring

The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.

Transcranial electrical stimulator (up to 1000 V), 12-channel electrical stimulator, low current stimulator, auditory and visual stimulators

Robust stimulators ensure high-quality responses during acquisition of brain evoked potentials and EMG exams. Transcranial electrical stimulator deserves the special attention. It is intended for stimulation of motor cortex to record motor evoked potentials from muscles. The stimulator ensures single pulse and train stimulation, as well as double train and train + pulse stimulation. Different kinds of stimulation can also be performed using a built-in electronic switch.

Flexible configurations to ensure any monitoring needs

The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery. You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible

Delivery set

  • Electronic block 32-channel “Neuro-IOM” 1 pcs.
  • USB cable (A-B) 1 pcs.
  • Network cable SCZ-1 1 pcs.
  • External block for connecting stimulating electrodes (channel 1-4) 1 pcs.
  • External block for connecting stimulating electrodes (channels 5-8) 1 pcs.
  • External block for connecting electrodes for direct nerve stimulation 1 pcs.
  • Electronic switch "Neuro-TES" 1 pcs.
  • Block of output electrodes IOM (A) (1-8) 1 pcs.
  • Block of output electrodes IOM (B) (9-16) 1 pcs.
  • Block of output electrodes IOM (C) (17-24) 1 pcs.
  • Block of output electrodes IOM (D) (25-32) 1 pcs.
  • Electrode-probe stimulating monopolar spherical with a rod length of 100 mm, article number SI1B0100S2526DRU 1 pcs.
  • Monopolar stimulating probe electrode (SI1I0100S2526DRU, with a rod length of 100 mm) 1 pcs.
  • Electrode-probe stimulating bipolar mini-plug with rod length 100 mm, article number SI2F0100S2526DRU 1 pcs.
  • Bipolar concentric stimulating probe electrode with rod length 100 mm, article number SI2C0100S2526DRU 1 pcs.
  • Subcutaneous needle electrode (MN4013D15SRU with needle length 13 mm, needle diameter 0.40 mm, with cable 150 cm long) 25 pcs.
  • Subcutaneous needle electrode twisted (MN4013D15A/SRU, with needle length 13 mm, needle diameter 0.40 mm, with cable 150 cm long) 10 pcs.
  • Corkscrew needle electrode, without screen, with needle length 5 mm, needle diameter 0.60 mm, with cable 150 cm long, article number MNCS0615DSRU 10 pcs.
  • Grounding electrode with lead cable EZ-3 (large) 1 pcs.
  • Grounding electrode with lead cable EZ-2 (middle) 1 pcs.
  • Electrode for ECG disposable D=26 mm 30 pcs.
  • Cable for connecting disposable electrodes with a “button” connector, touch-proof (white, 1 m) 2 pcs.
  • Cable for connecting a disposable electrode with a “button” connector, touch-proof (green, 2 m) 2 pcs.
  • Cable for connecting disposable electrodes with a “button” connector, touch-proof (red, 1 m) 2 pcs.
  • Cable for connecting disposable electrodes with a “button” connector, touch-proof (black, 1 m) 1 pcs.
  • Cable for connecting a disposable electrode with a “button” connector, touch-proof (yellow, 1 m) 1 pcs.
  • Cable for connecting disposable electrodes with a “button” connector, touch-proof (blue, 1 m) 2 pcs.
  • LED photostimulator FS-4 1 pcs.
  • Coagulator operation sensor 1 pcs.
  • Video cable SWA3525/10 (2RCA-2RCA, 10 m) 1 pcs.
  • Video Capture Device 1 pcs.
  • Dressing and fixing agent "Transpor" 4 pcs.
  • Installation kit for the computer program “Neuro-IOM.NET” 1 pcs.
  • Operation manual "Neuro-IOM" 1 pcs.
  • Operating manual “Electrodes for EMG and EP studies” 1 pcs.
  • User's Guide "Neuro-IOM.NET" 1 pcs.
  • Methodological recommendations “TOF stimulation” 1 pcs.
  • Methodological recommendations “Facial nerve” 1 pcs.
  • Methodological recommendations “Motor evoked potentials” (MEP) 1 pcs.
  • Methodological recommendations “Auditory evoked potentials” (AEP) 1 pcs.
  • Methodological recommendations “Somatosensory evoked potentials” (SSEP) 1 pcs.
  • Methodical recommendations "Thyroidectomy" 1 pcs.
  • Methodical recommendations “Pedicle screw test” 1 pcs.
  • Bag "Neurosoft" No. 4 1 pcs.
  • Warranty card 1 pcs.
  • License to use the computer program “Neuro-IOM.NET” 1 pcs.